gas boiler Agent condensate drain
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Condensate is what gets produced when your boiler is being used to heat your home or produce hot water. This is because when your boiler burns fuel, a chemical reaction causes produces carbon dioxide and water vapour by-products. Once enough heat is produced from this vapour, it's …Get Price
11/6/2015 · I would put condensate pipe on slight downward angle into rainwater pipe. It would be very convenient as the condensate pipe would only be exposed externally by a couple of inches into the downpipe which is just the other side of the wall to the boiler. sorethumb, Jun 10, 2015. #1.Get Price
The condensate expelled from a condensing boiler is acidic, with a pH between 3 and 4. Condensing boilers require a drainpipe for the condensate produced during operation. This consists of a short length of polymer pipe with a vapour trap to prevent exhaust gases from being expelled into the building.Get Price
What is a Condensate Pipe? | A Detailed Guide | BoilerhutGet Price
installing boiler condensate discharge pipes Figure 3 – Connection of a condensate pump - typical method (NB manufacturer's detailed instructions should be followed). Note – Any external pipe work should be insulated, pipe cut at 45 degrees and a drain/ leafGet Price
What is a Condensate Pipe? | A Detailed Guide | BoilerhutGet Price
Installer Guide to Condensate Discharge Pipe Installation. Correctly fitted condensate discharge pipes are vital to the function of a condensing gas or oil boiler. Due to a high volume of boiler breakdowns caused by the freezing of condensates, a guide has been published for installers by the HHIC.Get Price
2/11/2018 · Condensate trap. Posted on 2 November 2018 by DIYPlumbing. The condensate trap is a device inside a condensing boiler which collects water from the condensing process before it is expelled into the sewer via the condensate pipe. The purpose of the trap is to prevent toxic gases from entering the condensate pipe, and to manage the flow of Get Price
4/2/2009 · In most installations condensate can be removed through the normal gravity drain in conjunction with the boiler manufacturer's instructions. However, if a boiler has to be installed on internal walls or within basements the use of a boiler condensate tank pump or soak away can be the only solution for the installer.Get Price
condensate from a Condensing Boiler into a soil stack, waste pipe, external drain, rainwater hopper or an external soakaway. Condensate Check Valve The compact Condensate Non- Return Check Valve is used downstream to prevent condensate returning back Get Price
It can also work along with a pump system when the condensate needs to be pumped into the sanitary line. Unit is very simple to install as well as to maintain. Sani neutral (043) comes with the starter neutralizing agent. Possible connections: tankless water heater, air conditioning unit, boiler. Maximum temperature (°F): 160.Get Price
3/9/2019 · British Gas have recently done a service on my condensing boiler and put a not up to 'present standard' sticker on it due to condensate drain being routed to the outside path. When I replace the boiler for a condensing combi I would like to keep the boiler in the same position. Any thoughts how I can get the drain to the soil drain approx 5m away.Get Price
22/2/2020 · This was the first boiler of its type the gas fitter had installed. I remember him saying he didn't know if something should be open or closed, maybe it was this. The service engineer from the company who did the installation who came to check the boiler and reconnect the gas after the gas emergency man had capped it off said I could seal the opening between the flexible pipe from the boiler Get Price
9/2/2012 · A condensate pipe flowing into any existing drain should be fitted with a trap to prevent smells from the drain (the boiler MAY incorporate a trap but this should be verified). The flue should not drip excessively, if properly installed it would normally slope slightly upwards so that condensate in the flue will run back to the boiler and then to the condensate drain.Get Price
17/12/2019 · The condensate pipe is used to drain all the excess water produced from the condensing process in your boiler. Since the water, aka the condensate, is mildly acidic (that's because it is a by-product of the condensed waste gasses), it needs to be drained through a PVC or ABS pipe.Get Price
4.2 Condensate drain The flue gas line has an integrated condensate drain in the boiler connector. The condensate from the flue gas line flows directly into the boiler's trap (siphon). Follow local rules when draining condensate into munic-ipal sewage systems.Get Price
For example, compared to an old G-rated non-condensing gas boiler, an A-rated condensing model can save a detached home over £300 a year in energy costs. To experience the ongoing benefits of a gas condensing boiler, you'll need to make sure it stays in good condition - and among other things, this means keeping the boiler condensate trap clean.Get Price
16/12/2018 · My boiler has an outlet fitting for this condensate water but the manual doesn't say what kind of of tubing should be used to drain it. The other tubing attached to my boiler is copper (for the water in/out) and steel or iron for the gas connection.Get Price
The condensate from the boiler should, where possible, be discharged into the internal drainage of the household drainage system Internal condensate discharge pipework must be a minimum diameter of 19mm (which is generally viewed as 22mm OD) and mustGet Price
installing boiler condensate discharge pipes Figure 3 – Connection of a condensate pump - typical method (NB manufacturer's detailed instructions should be followed). Note – Any external pipe work should be insulated, pipe cut at 45 degrees and a drain/ leafGet Price
13/11/2016 · condensate drain fittings pipe. Tomeng New Member. Hi, I've been told by a gas safe engineer that the condensate drain from a combi boiler must only use pipe that has been joined with solvent weld. (I used 22mm barrier pipe and speed-fit elbow, joining into a 40mm waste pipe that has plastic compression fittings).Get Price
1/6/2018 · Let me share the 6 most important facts about condensates with you below, so you can consider yourself clued-up. 1. All modern boilers can't run without one. Essentially, a condensate pipe takes waste water away from the boiler. All modern condensing boilers require a condensate pipe to run to a suitable drain.Get Price
1/2/2009 · Jan 14, 2009. #1. just been to a job. found a tundish valve (visual warning device of liquid passing, open to atmosphere) connected directly to condensate of remeha boiler. we dont need to talk about the boiler, it wouldnt of been my option but one of those things. technically i understand, condensate is part of flue system, as i had never seen Get Price